CHN Analyzer is a proven instrument which can determine the elemental concentrations in Organic and other type of materials given sample. It has the capability of handling a wide variety of sample types in the field of pharmaceuticals, polymers, chemicals, environmental and energy, including solids, liquids, volatile and viscous samples It is used to measure Carbon (C), Hydrogen (H) and Nitrogen (N). Sample sizes may differ depending on system, but most often in around a few mg. For some sample matrices larger mass is preferred due to sample heterogenicity.

This instrument uses classical Pregl-Dumas method of combustion in a pure oxygen environment to oxidize the sample into simple compounds which are then detected with thermal conductivity detection and infrared spectroscopy. Separation of interference is done by chemical reagents. The design has been field-proven in thousands of laboratories around the world. High-speed microprocessor control, solid-state components and built-in diagnostics provide confidence in performance and reliability

Automatic CHN Analyzer Manufacturer for Accurate Elemental Analysis

An Automatic CHN Analyzer is a laboratory instrument used to determine the carbon, hydrogen, and nitrogen content in different samples. It plays an important role in research laboratories, chemical industries, educational institutions, and material testing facilities where elemental composition analysis is required.

ARICO, offers analytical instrument solutions for laboratory and industrial testing needs. As an Automatic CHN Analyzer Manufacturer, ARICO is a brand to explore when looking for equipment for elemental analysis and sample testing.

Choosing a reliable Automatic CHN Analyzer Supplier helps laboratories identify suitable equipment based on their sample types, testing requirements, accuracy expectations, and workflow. Automated analysis can also help streamline routine laboratory operations and support consistent testing procedures.

For laboratories and industries looking for elemental analysis equipment, ARICO provides a starting point for exploring analytical instruments suited to their requirements.

ModelCHN-001
Measurement Range1. Cad: 50ppm or 0.005%-100%
2. Had: 200ppm or 0.02%-50%
3. Nad: 80ppm or 0.008%-50%
Standard Complied ASTM D-5373
Accuracy1. Cad: 0.5%
2. Had: 0.15%
Nad: 0.08%
Single Sample Analysis Time6-7min
Sample weighingRecommended: 100-120mg
Test method1. Cad: Optimized for low noise, non-dispersive infrared absorption method
2. Had: Optimized for low noise, non-dispersive infrared absorption method
3. Nad: Optimized for low drift, thermal conductivity detection method
Gas specifications required by experiments1. Carrier gas: helium, purity higher than 99.996%, 0.25 ± 0.01MPa
2. Assistant gas: oxygen, only when carbon and hydrogen measured, the purity higher than 99.50%, when measuring nitrogen, purity higher than 99.995%, 0.25 ± 0.01MPa
3. Power gas: compressed air or nitrogen, must be free of oil and water, 0.25 ± 0.01MPa
Furnace typeResistance furnace, the maximum temperature 1050°C
Automatic sample-falling head30 samples loaded at one time
Power supply1. Detecting Power Supply: AC220V ± 22V, 50Hz, 2A
2. Heating unit: AC220V ± 22V, 50Hz, 20A
Host machine dimension (mm)710×690×930
Host machine weight (kg)120